-
SAS to SAS RAID subsystem
-
Redundant or single RAID controller
-
EonPath® multi-pathing, load-balancing software
-
4 or 2 SAS 4x wide host ports
-
Hardware RAID6 engine by dedicated ASIC400 chipsets
-
Superior performance w/ uncomplicated connectivity
-
16 SAS disk drives
-
Expansion to 80TB via a 4x wide expansion port
-
Corresponding JBODs: S16S-J1000-R (dual-controller); S16S-J1000-S (single-controller)
Model |
Host Interface |
Drive Interface |
Controller |
Form Factor |
S16S-R1030 |
4 multi-lane wide ports (SFF-8470) |
SAS |
Dual |
3U rack-mount |
Corresponding JBODs
-
Hardware RAID parity computing
RAID |
JBOD |
Max. number |
S16S-R1030 |
S16S-J1000-R |
3 |
Information about supported disk drives, network components, and software compatibility, please refer to our VIPRoom website (for authorized dealers).
RAID
-
Hardware RAID5 & RAID6
-
Supports RAID 0, 1 (0+1), 3, 5, 6, 10, 30, 50, 60, NRAID
-
RAID Migration
-
Configurable stripe size and write policy per array
-
Multiple Global, Dedicated, & Enclosure-specific hot-spares
-
Intelligent Drive Handling:
-
In degraded mode: skips irreparable blocks to continue rebuild
-
In normal operation: data-block verification and repair
Host Interface
-
4 (S16S-R1030) or 2 (S16S-G1030) SAS wide ports
-
12Gbps bandwidth (half duplex) per port
-
Concurrent I/O commands
-
Tagged command queuing up to 1024
-
Max. command queue up to 1024
-
Fault-tolerant host links with the EonPath multi-pathing software
-
Included cables:
-
S16S-R1030 – 2x SFF-8088-to-SFF-8470 120cm cables
Drive Interface
-
16 3.0Gbps SAS, hot-swappable drive trays
-
Accommodates 1-inch pitch, 3.5-inch SAS disk drives
-
S.M.A.R.T. and NCQ support
-
Automatic bad-sector reassignment
-
Dedicated bandwidth to each connected drive
-
In-band enclosure service through the expansion links from expansion enclosures
-
Path redundancy to disk drives via edge expanders and expanders on JBOD controllers through separate SAS domains
-
MUX kits with port selectors for dual-controller access to SATA drives
System Components
-
High density, smartly managed 3U enclosure
-
Dual redundant or single RAID controller
-
One DIMM module with capacities from 512MB to 2GB
-
Redundant, hot-swappable 530W power supply units
-
Redundant, dual-speed cooling modules
-
Sixteen (16), hot-swappable drive trays
-
Two (2) forearm handles
-
Li-Ion battery backup unit (BBU), life expectancy and charge level aware
Management
-
COM1 serial port for local access to firmware-embedded utility
-
COM2 for UPS connection
-
Automated cache flush and caching mode operation per enclosure status
-
GUI, Telnet, and SSH system monitoring via Ethernet
-
Java-based SANWatch software
-
Firmware-embedded manager via RS-232C (audio jack) that is platform independent
-
Widest range of event notification methods including email, LAN broadcast, fax, SNMP traps, SMS, and MSN
-
LCD keypad panel for monitoring and access to all configuration options
-
Variable logical drive options per DIMM size
-
Module status LED indicators:
-
Two (2) per drive tray
-
Seven (7) per controller module
-
One (1) per power supply unit
-
One (1) per BBU module
-
Two (2) per cooling module
-
Presence detection & thermal sensors via I2C bus
Power Supply Module
Redundant hot-swappable power supplies with PFC
Input |
100VAC at 9A, 240VAC at 4.5A with PFC (auto-switching) |
47 to 63Hz |
Output |
(Maximum output: 530 Watts) |
+12.0V |
32A max. |
+ 5.0V |
32A max. |
+3.3V |
30A max. |
Cooling Module
Redundant dual-thermal-fan cooling modules
Maximum air flow |
90CFM (high speed);
70.7CFM (low speed) |
Environmental Specifications
Operating temperature: |
5º to 40ºC (35°C if battery is applied) |
Non-operating temperature: |
- 40º to 60ºC |
Relative humidity: |
5 to 95%, non-condensing |
Operating altitude: |
Operating: 0 to 12,000 ft |
Dimensions
-
Package: 423(H) x 567(W) x 772(D) mm (16.7 x 22.3 x 30.4 inches)
System Weight
-
Net weight: 28.5kg (62.7 pounds)
-
Gross weight: 30.5kg (67.1 pounds)